Your Vehicle: 2001 Ford Escort ZX2 L4-2.0L DOHC VIN 3
 
Vehicle » Maintenance » Filters » Air Cleaner Housing » Service and Repair  
 
 
  Service and Repair  
 

REMOVAL

NOTE: Zetec shown, S/R series similar

  

  1. Loosen the clamp and separate the air cleaner outlet tube from the Air Cleaner (ACL) .

  

  1. Disconnect the Mass Air Flow (MAF) sensor electrical connector.

  

  1. Open the air cleaner clamp and remove the air cleaner cover and the air cleaner (ACL) element.

  

  1. Remove the crankcase pressure relief hose.

  

  1. Remove the bolts and remove the air cleaner housing.

INSTALLATION

  1. To install, reverse the removal procedure.